Files
resonance-engine/docs/forensic_audit_report.md
T

7.3 KiB
Raw Blame History

Forensic Audit of Data - Grid Comparison Analysis

Date: 2026-03-12 06:22 GMT+7
Analysis Target: Probe data from 256×256 grid vs Original 1024×1024 grid
Purpose: Find differences from original grid and identify root causes

Executive Summary

A forensic audit of the 256×256 grid simulation data reveals significant deviations from the expected scaling behavior of the original 1024×1024 grid. The most critical findings are:

  1. Power scaling is 4× less efficient than expected (25.3% vs 100%)
  2. Guardian density is 7.2% higher than scaled expectation
  3. Grid size is below the stability boundary (256 ≤ 768)
  4. System shows coherent behavior despite being in unstable region

Detailed Findings

1. Grid Scaling Parameters

Parameter Original (1024×1024) Current (256×256) Expected Scaling Actual Difference
Grid Size 1024×1024 256×256 1/4 linear 1/4 linear ✓ Correct
Area 1,048,576 cells 65,536 cells 1/16 (0.0625) 1/16 (0.0625) ✓ Correct
Guardian Count 194 13 12.125 (194 × 0.0625) 13 +7.2%
Guardian Density 1.850×10⁻⁴ 1.983×10⁻⁴ Same as original +7.2% ⚠️ Higher
Power Baseline 150W 37W 9.375W (150 × 0.0625) 37W +295%

2. Critical Anomalies

2.1 Power Scaling Discrepancy

  • Expected: Power should scale with area (1/16 = 6.25% of original)
  • Actual: Power scales to 24.7% of original (4× higher than expected)
  • Implication: Non-linear power consumption at small grid sizes
  • Possible Cause: Fixed overhead, memory bandwidth saturation, or GPU architecture limits

2.2 Guardian Formation Analysis

  • Threshold: RHO_THRESH = 1.00022f (optimized for 256×256)
  • Creation Rho: Average 1.00023 (range: 1.00022-1.00024)
  • Spatial Distribution: Guardians cover 24.4% of X-axis, 32.3% of Y-axis
  • Accretion Rate: Average 0.0049 mass per creation event
  • Finding: Guardians form correctly but at slightly higher density than scaled expectation

2.3 Stability Boundary Concern

  • Harmonic Analysis: Grid size 256 corresponds to "Two octaves (1/4)" musical interval
  • Stability Boundary: 768 (identified in harmonic analysis)
  • Risk: Operating below stability boundary could lead to:
    • Energy collapse (magnitude: -6.86 according to harmonic analysis)
    • Phase transitions
    • Non-linear response amplification

3. Probe Data Analysis (Cycles 600-607)

3.1 System State During Probe A (Metabolic Injection)

  • Probe State: INJ (mass injection active)
  • Omega Stability: All values within [1.2410, 1.2778] (stable range)
  • Mass Accumulation: Steady increase from 14.91 to 15.07
  • Total Mass (MTotal): Stable at ~65627.40
  • Guardian Count: Constant at 13 (no deaths during probe)

3.2 Ghost Particle Analysis

  • Total Particles: 156 ghost particles detected
  • Average Position: (125.2, 128.5) - centered in grid
  • Average Mass: 0.62 per particle
  • State: All in PULSE state (active accretion)
  • Distribution: Evenly distributed across grid

4. Comparison with Original Grid Behavior

4.1 Expected vs Observed Scaling Laws

Scaling Law Expected Relationship Observed Relationship Deviation
Power vs Area P ∝ A (linear) P ∝ A^0.5 (square root) Non-linear
Guardians vs Area G ∝ A (linear) G ∝ A^1.072 (slightly super-linear) Minor
Memory vs Area M ∝ A (linear) M ∝ A (linear) ✓ Correct

4.2 Efficiency Metrics

  • Computational Efficiency: 25.3% of expected
  • Guardian Formation Efficiency: 107.2% of expected (slightly over-efficient)
  • Memory Efficiency: 100% of expected
  • Overall System Efficiency: Sub-optimal due to power scaling issue

5. Root Cause Analysis

5.1 Primary Suspect: Fixed Overhead

  • GPU kernels have fixed overhead regardless of grid size
  • Memory transfers, kernel launches, synchronization
  • Becomes dominant at small grid sizes

5.2 Secondary Suspect: Memory Bandwidth Saturation

  • Small grids may not fully utilize memory bandwidth
  • Inefficient memory access patterns at small scales
  • Cache effects different at 256×256 vs 1024×1024

5.3 Tertiary Suspect: Guardian Interaction Range

  • Guardian interaction radius may not scale correctly
  • Fixed interaction range in lattice units vs physical units
  • Could cause increased density effects

6. Recommendations

6.1 Immediate Actions

  1. Verify power measurement methodology - ensure accurate power reading
  2. Profile kernel execution times - identify fixed overhead components
  3. Test intermediate grid sizes - 512×512, 384×384 to map scaling curve

6.2 Short-term Investigations

  1. Memory bandwidth analysis - measure effective bandwidth at different grid sizes
  2. Guardian parameter validation - verify all scaled parameters:
    • DRAIN_RADIUS (4 vs 16 original)
    • SINK_RADIUS (6 vs 24 original)
    • SINK_RATE (0.0003125 vs 0.005 original)
    • RHO_THRESH (1.00022 vs 1.01 original)

6.3 Long-term Considerations

  1. Develop non-linear scaling model - account for fixed overhead
  2. Optimize for small grid operation - specialized kernels for <512 grids
  3. Implement adaptive guardian density - dynamic adjustment based on grid size

7. Data Quality Assessment

7.1 Data Completeness

  • Cycle data: 8 complete records (600-607)
  • Guardian data: 13 creation events fully documented
  • Ghost particle data: 156 particles with complete state
  • ⚠️ Limited time range: Only covers Probe A (cycles 600-649)
  • Missing data: Probes B, C, D not captured in available data

7.2 Data Consistency

  • Guardian count stable throughout observed cycles
  • Omega values within expected physical range
  • Mass conservation: MTotal stable within 0.01%
  • Spatial distribution: Guardians and particles evenly distributed

7.3 Data Gaps

  1. No data for cycles 0-599 (initialization and warmup)
  2. No data for cycles 608-799 (recovery after Probe A)
  3. No data for Probe B (cycle 800 - lattice shear)
  4. No data for Probe C (cycles 1100-1199 - VRM silence)
  5. No data for Probe D (cycles 1400-1499 - vacuum trap)

8. Conclusion

The forensic audit reveals that while the 256×256 grid functions correctly from a computational perspective, it exhibits significant scaling anomalies compared to the original 1024×1024 grid:

  1. Power consumption is 4× higher than area scaling predicts
  2. System operates below the identified stability boundary (256 < 768)
  3. Guardian density is slightly elevated but within acceptable bounds
  4. Core physics remains coherent despite scaling issues

Primary Recommendation: Focus investigation on the power scaling discrepancy, as it represents the most significant deviation from expected behavior and likely indicates fundamental architectural constraints at small grid sizes.

Secondary Recommendation: Collect more complete data covering all probe phases (A-D) to fully characterize system response across different perturbation types.


Report generated by Forensic Audit Script v1.0
Data Sources: probe_final_results.csv, probe_output_20260311_220349.txt, harmonic_analysis_results.json
Analysis Time: 2026-03-12 06:22 GMT+7